1. Safety Requirements

1.1 Environmental Requirements

Precautions:

  • Avoid high temperature, open flames, corrosive gases, humid or dusty environments to prevent equipment failure.
  • For your personal safety, use the test leads provided with the meter. Before use, inspect and ensure they are in good condition.
  • Use the correct input terminals, functions, and ranges for measurements. Do not exceed the specified input limits for each range to prevent damage to the meter.

Keep Away From:

  • Heaters: Avoid overheating or fire risk
  • Water, chemicals, solvents: Leakage may damage equipment or cause fire
  • Strong magnetic devices: Prevent magnetic field interference with normal operation

Disposal:

Do not dispose of old batteries or equipment with household waste. Dispose according to national or local regulations.

2. Product Overview

The DST-210 is a comprehensive multifunctional device launched by FNIRSI, integrating oscilloscope and multimeter capabilities into one portable unit.

Oscilloscope Features:

  • Bandwidth: 10 MHz
  • Sample Rate: 100 MSa/s
  • Display: 2.8-inch TFT color screen with clear, intuitive interface
  • Triggering: Edge trigger, auto/normal/single modes
  • Measurements: Automatic measurement of frequency, period, amplitude, peak-to-peak, effective value, duty cycle, and more
  • Waveform Storage: Save and recall waveforms
  • USB Data Export: Transfer data to PC via USB connection

Multimeter Features:

  • Comprehensive Functions:
    • AC/DC Voltage measurement
    • AC/DC Current measurement
    • Resistance, Capacitance
    • Diode test / Continuity test
    • Frequency, Temperature
    • Data Hold function
    • LIVE wire detection (live/neutral)
    • Record mode and automatic measurement
  • Protection: Overload protection and low battery indication

Portable Design:

  • Display: 2.8-inch TFT color screen
  • Battery: Built-in high-capacity rechargeable lithium battery (3000 mAh)
  • Battery Life: Supports long standby time (10 hours)
  • Design: Compact and lightweight, suitable for mobile use

The FNIRSI DST-210 provides users with powerful, flexible functionality and a portable operating experience. It is an ideal multifunctional instrument for professionals, factories, schools, hobbyists, and home use.

2.1 Product Operation Diagram

page 22 2

Front Panel Controls:

  • Mode Switch Button: Switch between oscilloscope and multimeter modes
  • Rotary Dial Selector: Select measurement function
  • Automatic Measure Key: Enable automatic measurements
  • Run/Pause Button: Start/stop waveform acquisition
  • Confirm Button: Confirm selections
  • Selection Key: Navigate menu options

Rotary Dial Positions:

  • AUTO: Automatic range
  • Ω (Ohm): Resistance measurement
  • Diode: Diode test
  • Frequency: Frequency measurement
  • mA: AC/DC milliamp current
  • V: AC/DC voltage
  • Buzzer: Continuity test (with buzzer)
  • Capacitor: Capacitance measurement
  • Temperature: Temperature measurement
  • A: AC/DC current (up to 10A)

Connectors:

  • COM Jack: Common terminal (black lead)
  • V/Ω Jack: Voltage/Resistance terminal (red lead)
  • mA Jack: Milliamp current terminal
  • 10A Jack: High current terminal (up to 10A)
  • BNC Input: Oscilloscope signal input
  • Type-C Port: USB charging port (5V/1A)
  • Reset Hole: Firmware reset button

Additional Features:

  • Built-in kickstand for hands-free viewing
  • LED indicators for power and charging status

3. Technical Specifications

page 23 1

Oscilloscope Specifications:

Bandwidth: 10 MHz (-3 dB)

Input Channels: 1 channel (BNC connector)

Sample Rate: 100 MSa/s (single-shot)

Vertical Sensitivity: 50 mV/div – 50 V/div (1-2-5 steps)

Input Impedance: 1 MΩ // 20 pF

Maximum Input Voltage: 400V (DC + AC peak)

Vertical Resolution: 8 bits

Timebase Range: 100 ns/div – 100 s/div

Trigger Modes: Auto, Normal, Single

Trigger Source: CH1

Trigger Types: Edge (rising/falling)

Record Length: 2048 points

page 24

Automatic Measurements:

  • Frequency (Hz)
  • Period (s)
  • Peak-to-Peak Voltage (Vpp)
  • RMS Voltage (Vrms)
  • Maximum Voltage (Vmax)
  • Minimum Voltage (Vmin)
  • Duty Cycle (%)

Multimeter Specifications:

DC Voltage: 0 – 600V, Accuracy: ±(0.5% + 3 digits)

AC Voltage (True RMS): 0 – 600V, Accuracy: ±(1.0% + 5 digits)

DC Current (mA): 0 – 600 mA, Accuracy: ±(1.0% + 3 digits)

AC Current (mA): 0 – 600 mA, Accuracy: ±(1.5% + 5 digits)

DC Current (A): 0 – 10A, Accuracy: ±(1.5% + 5 digits)

AC Current (A): 0 – 10A, Accuracy: ±(2.0% + 5 digits)

Resistance: 0 – 60 MΩ, Accuracy: ±(1.0% + 3 digits)

Capacitance: 0 – 10 mF, Accuracy: ±(3.0% + 5 digits)

Frequency: 10 Hz – 10 MHz, Accuracy: ±(0.1% + 2 digits)

Duty Cycle: 1% – 99%, Accuracy: ±(1% + 1 digit)

Temperature (K-type): -20°C – 400°C, Accuracy: ±(2.0% + 3°C)

Diode Test: 0 – 2V, Accuracy: ±(1% + 2 digits)

Continuity Test: < 30 Ω, Buzzer alert

General Specifications:

Display: 2.8-inch TFT LCD (320×240)

Battery: 3000 mAh lithium-ion rechargeable

Battery Life: Approx. 10 hours (typical use)

Charging Port: Type-C USB (5V/1A)

Charging Time: Approx. 3 hours

Data Storage: Internal memory for waveform storage

USB Interface: Type-C (data transfer to PC)

Operating Temperature: 0°C to 40°C

Storage Temperature: -20°C to 60°C

Humidity: < 80% RH (non-condensing)

Dimensions: 148 mm × 73 mm × 30 mm

Weight: Approx. 200g

page 26 1

4. Operation Guide

4.1 Oscilloscope Mode Operation

Basic Operation:

Step 1: Power On

  • Press and hold power button for 2-3 seconds
  • Device displays startup screen

Step 2: Select Oscilloscope Mode

  • Press MODE button to switch to oscilloscope mode
  • Screen displays oscilloscope interface with grid

Step 3: Connect Signal

  • Connect BNC probe to oscilloscope input
  • Connect probe tip to circuit under test
  • Connect probe ground clip to circuit ground

Step 4: Adjust Display

  • Use UP/DOWN keys to adjust vertical scale (V/div)
  • Use LEFT/RIGHT keys to adjust timebase (s/div)
  • Press AUTO button for automatic setup

Step 5: Trigger Settings

  • Press MENU to access trigger settings
  • Select trigger mode: Auto, Normal, or Single
  • Adjust trigger level using UP/DOWN keys
  • Choose trigger edge: Rising or Falling

Step 6: Measurements

  • Press AUTO MEASURE button
  • Display shows automatic measurements: Frequency, Period, Vpp, Vrms, Vmax, Vmin, Duty cycle

Step 7: Save Waveform

  • Press MENU → Save
  • Select memory location (1-10)
  • Confirm to save current waveform

Step 8: Recall Waveform

  • Press MENU → Recall
  • Select saved waveform from list
  • Press CONFIRM to load

4.2 Multimeter Mode Operation

Voltage Measurement (AC/DC):

  1. Turn rotary dial to V position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Press MODE to select AC or DC voltage
  4. Connect probes across the voltage source
  5. Read measurement on display

Current Measurement (AC/DC):

For mA range (0-600 mA):

  1. Turn rotary dial to mA position
  2. Connect red lead to mA jack, black lead to COM jack
  3. Press MODE to select AC or DC current
  4. Connect meter in series with circuit
  5. Read measurement on display

For A range (0-10A):

  1. Turn rotary dial to A position
  2. Connect red lead to 10A jack, black lead to COM jack
  3. Press MODE to select AC or DC current
  4. Connect meter in series with circuit
  5. Read measurement on display

⚠ Do not measure > 10A or use for > 10 seconds continuously

Resistance Measurement:

  1. Turn rotary dial to Ω position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Disconnect power from circuit being tested
  4. Connect probes across resistor
  5. Read resistance value on display

Capacitance Measurement:

  1. Turn rotary dial to capacitor position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Discharge capacitor completely before testing
  4. Connect probes to capacitor terminals
  5. Wait for reading to stabilize (may take several seconds)
  6. Read capacitance value on display

Diode Test:

  1. Turn rotary dial to diode position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Connect red probe to anode, black probe to cathode
  4. Forward voltage drop displayed (typically 0.4-0.7V for silicon)
  5. Reverse connection shows ‘OL’ (open) for good diode

Continuity Test:

  1. Turn rotary dial to buzzer position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Touch probes to both ends of circuit path
  4. Buzzer sounds if resistance < 30Ω (continuity)
  5. Display shows resistance value

Frequency Measurement:

  1. Turn rotary dial to frequency position
  2. Connect red lead to V/Ω jack, black lead to COM jack
  3. Connect probes to signal source
  4. Display shows frequency (Hz, kHz, or MHz)
  5. Duty cycle also displayed (if square wave)

Temperature Measurement:

  1. Turn rotary dial to temperature position
  2. Connect K-type thermocouple to meter
  3. Place thermocouple probe at measurement point
  4. Wait for reading to stabilize
  5. Read temperature in °C or °F

Live Wire Detection:

  1. Turn rotary dial to AUTO position
  2. Hold meter near AC power wire (do not touch)
  3. Display indicates LIVE or NEUTRAL wire
  4. LED indicator also shows status

Data Hold Function:

  • Press HOLD button to freeze current reading
  • ‘HOLD’ indicator appears on display
  • Press HOLD again to resume normal operation

5. Quick Start Guide

Getting Started:

Step 1: Unpack and Inspect

Check package contents:

  • DST-210 main unit
  • BNC oscilloscope probe
  • Test leads (red and black)
  • K-type thermocouple
  • USB Type-C charging cable
  • User manual

Inspect for any damage from shipping

Step 2: Initial Charging

  • Connect USB Type-C cable to meter and power adapter
  • Charge for 3 hours before first use
  • LED indicator shows charging status
  • Red LED: Charging
  • Green LED: Fully charged

Step 3: Power On

  • Press and hold power button for 2-3 seconds
  • Display lights up with FNIRSI logo
  • Device enters default mode

Step 4: First Measurement

Multimeter Mode:

  1. Turn dial to desired function
  2. Connect appropriate test leads
  3. Perform measurement

Oscilloscope Mode:

  1. Press MODE button to switch to scope
  2. Connect BNC probe
  3. Press AUTO for automatic setup
  4. View waveform on screen

6. Troubleshooting

Device won’t power on

Possible Cause: Battery dead

Solution: Charge for 30 minutes

Possible Cause: Power button held insufficient time

Solution: Hold button 2-3 seconds

No waveform display

Possible Cause: No signal input

Solution: Check probe connection

Possible Cause: Wrong V/div scale

Solution: Press AUTO button

Possible Cause: Trigger not set

Solution: Adjust trigger level

Multimeter shows ‘OL’

Possible Cause: Open circuit

Solution: Check connections

Possible Cause: Range too low

Solution: Change to higher range

Possible Cause: Test lead broken

Solution: Replace test leads

Inaccurate readings

Possible Cause: Low battery

Solution: Charge battery

Possible Cause: Needs calibration

Solution: Contact service center

Possible Cause: Wrong function

Solution: Check dial position

Display is dim

Possible Cause: Low battery

Solution: Charge battery

Possible Cause: Brightness low

Solution: Adjust in settings menu

Won’t charge

Possible Cause: Cable damaged

Solution: Replace USB cable

Possible Cause: Adapter issue

Solution: Try different adapter

Possible Cause: Port dirty

Solution: Clean Type-C port

Freezes or crashes

Possible Cause: Software error

Solution: Press reset button

Possible Cause: Memory full

Solution: Delete saved waveforms

7. Maintenance

Regular Maintenance:

Cleaning:

  • Power off device before cleaning
  • Wipe display with soft, dry cloth
  • Do not use chemical solvents or abrasive cleaners
  • Clean BNC connector with contact cleaner if necessary
  • Keep USB port free from dust and debris

Battery Care:

  • Charge battery at least once every 3 months if not in use
  • Avoid complete discharge for extended periods
  • Do not expose to extreme temperatures during charging
  • Replace battery if capacity significantly decreases

Storage:

  • Store in cool, dry place (0°C to 40°C)
  • Keep in protective case when not in use
  • Remove batteries if storing for extended period
  • Avoid direct sunlight and high humidity

Probe Maintenance:

  • Inspect test leads regularly for damage
  • Check for exposed wires or cracks in insulation
  • Replace damaged probes immediately
  • Keep probe tips clean and sharp
  • Store probes properly to prevent damage

Calibration:

  • Professional calibration recommended every 12 months
  • Contact FNIRSI service center for calibration service
  • Keep calibration certificate for warranty purposes

Warnings:

  • ⚠ Do not disassemble the device – no user-serviceable parts inside
  • ⚠ Do not expose to water or excessive moisture
  • ⚠ Do not drop or subject to strong impact
  • ⚠ Use only specified replacement parts and accessories

8. Contact Us

Manufacturer:

Company: Shenzhen Zhuo Yue Xin Technology Co., Ltd.

Brand: FNIRSI

Product: DST-210 Multifunctional Oscilloscope Multimeter

Model: DST-210

Version: V1.2

Support:

Website: www.fnirsi.com

Email: support@fnirsi.com

Downloads: Manuals, software, firmware at www.fnirsi.com/support

Service: Available worldwide

9. Warranty Information

Warranty Coverage:

  • Period: 12 months from date of purchase
  • Covers: Manufacturing defects and component failures
  • Includes: Free repair or replacement (at manufacturer’s discretion)

Warranty Exclusions:

  • ✗ Damage from misuse, abuse, or accidents
  • ✗ Damage from unauthorized modifications or repairs
  • ✗ Normal wear and tear (battery, test leads)
  • ✗ Damage from improper storage or transportation
  • ✗ Damage from exposure to liquids or extreme conditions
  • ✗ Cosmetic damage that doesn’t affect functionality

Warranty Claim Procedure:

  1. Contact support@fnirsi.com with:
    • Proof of purchase (receipt or invoice)
    • Serial number (on back of device)
    • Detailed description of issue with photos/videos
  2. Await response with instructions (1-2 business days)
  3. Ship device to designated service center if required
  4. Repair or replacement completed within 15 business days
  5. Device returned via courier

Important Notes:

  • Keep proof of purchase for warranty service
  • Register product at www.fnirsi.com for extended support
  • Warranty is valid worldwide
  • Customer responsible for shipping costs to service center
  • Return shipping covered by FNIRSI for warranty repairs
  • Warranty does not cover accessories (probes, cables)

For latest updates, firmware, and support: www.fnirsi.com

Similar Posts

  • FNIRSI-1014D Oscilloscope User Manual

    2-in-1 Digital Oscilloscope with Signal Generator Product Overview The FNIRSI-1014D is a versatile 2-in-1 device combining a dual-channel digital oscilloscope with a built-in signal generator. This cost-effective desktop instrument is designed for both maintenance professionals and R&D engineers, offering comprehensive features and high practicality. Key Specifications Major Features Oscilloscope Functions: Signal Generator Features: Data Management:…

  • FNIRSI DPS-150 English User Manual

    ⚠️ User Notice Important Safety Information Product Introduction FNIRSI DPS-150 is a high-precision portable CNC DC power supply with advanced digital control capabilities. It features adjustable voltage and current output, multiple protection mechanisms, PC software control, and a compact portable design ideal for electronics development, testing, and maintenance work. Key Features Panel Introduction Front Panel Components…

  • FNIRSI-1013D Oscilloscope User Manual

    Product Overview The FNIRSI-1013D is a full-featured, highly practical, and cost-effective dual-channel touchscreen oscilloscope designed for maintenance professionals and R&D engineers. This portable instrument combines professional performance with intuitive touchscreen operation for maximum convenience. Key Specifications Major Features Oscilloscope Functions: Touchscreen Interface: Data Management: Portable Design: Order your 1013D today – 2-day UK delivery, 60-day…

  • FNIRSI LCR-P1 User Manual

    NOTICE TO USERS 1. PRODUCT INTRODUCTION The FNIRSI LCR-P1 Transistor Tester is a high-precision, multifunctional electronic testing device designed specifically for electronic engineers, technicians, and electronics enthusiasts. This device is intended for detecting and analyzing the performance and characteristics of semiconductor components such as: Key Features: Advanced Testing Capabilities: Component Detection: 2. PANEL INTRODUCTION Order your LCR-P1…

  • FNIRSI 2D15P User Manual

    ⚠️ SAFETY INFORMATION Safety Terms and Symbols WARNING: Indicates conditions or actions that could result in personal injury or loss of life. CAUTION: Indicates conditions or actions that may damage the product or other property. DANGER: Indicates that performing this operation may cause injury. Safety Precautions PRODUCT OVERVIEW What’s in the Box Standard Accessories: Order…

  • FNIRSI 2C53T User Manual

    50MHz Dual Channel Oscilloscope Multimeter NOTICE TO USERS 1. PRODUCT INTRODUCTION The FNIRSI-2C53T is a comprehensive, highly practical 3-in-1 dual-channel digital oscilloscope designed for maintenance and R&D professionals. This device combines three major functions: Oscilloscope, Multimeter, and Signal Generator. Key Features: Oscilloscope Specifications: Multimeter Specifications: Signal Generator: Display & Power: 2. PANEL INTRODUCTION Order your 2C53T today – 2-day UK…